Devanco Canada

 
User Name:
Password:
Remember Me:
Forgot your password
Request a Login

50-106

Take-Up Reel 2-Wire Metal 18-ga 20ft

  • 18-gauge
  • 20 ft extended
  • Take up reels are NOT recommended for use with any failsafe type edge. Use coil cord only.
  • Also called Reel cord
LMRRUL

LiftMaster Monitored Retro Reflective Photo Eye w/Heater 2018 UL325

  • Features integrated diagnostics with our 2018 UL® 325 Gate Operators.
  • Versatile Solution for entrapment protection.
  • Long-Range Sensing Distance of up to 50 ft. (LMRRUL)
  • Built-In Heater for dependable performance in most environments.
  • Increased Beam Angle for simple reliable alignment.
  • Versatile Gimble Bracket for fine alignment and adjustability.
  • .......more details
LMWEKITU

LiftMaster Wireless Edge Kit Monitored

  • Meets 2016 UL 325 requirements
  • low-energy Bluetooth® transmission up to 130 ft. range
  • Integrated Diagnostics with Gate Operator Speed Installation
  • Protects up to 8 entrapment points
  • Receiver accepts up to 4 transmitters
  • Transmitter accepts up to 2 wired resistive edges
  • .......more details
LOOPDETLM

Liftmaster Plug-in Loop Detector for Liftmaster gate operators

  • Plug-in Loop detector for CSW24V CSL24V AND LA500
  • Includes diagnostic and test feature
  • 12VDC/3mA power draw
  • For exit interrupt or shadow loop applications
  • Activates only when a vehicle passes over a loop
  • 8 sensitivity levels plus boost to ensure that vehicles are easily identified
  • .......more details
CPS-U

LiftMaster Commercial Protector System Eyes

  • For LiftMaster Logic 2 3 4 & 5 commercial operators only
  • NOT for outdoor applications
  • Allows activation of the timer-to-close
  • Mounting hardware included
  • Sensing distance of 30 feet
  • CDO 2010 Ready
  • .......more details
CPS-UN4

LiftMaster Commercial Protector System Thru-Beam Eyes NEMA4

  • Waterproof photoeyes.
  • for direct connect to operators with Logic boards. L3 L4 L5
  • Receiving Eye - A: 50-50997 Sending Eye - A: 50-50998
  • These eyes will also work on the Micanan UL325 monitored operators
LMUNTG

LiftMaster Glass Mount Parking Pass Tag Sold Per Card

  • A security-enhanced RFID passive transmitter for use with the LIftMaster LMSC1000 Long Range Vehicle Access-Card Reader.
  • Glass-mount means it can be affixed to either the windshield of a car or to the headlight housing of the vehicle
  • Aligns with the cone-shaped detection zone from LiftMaster RFID Reader and activates it to open gate barrier
  • Added security of single mount use: shuts off if removed after adhering to a surface
  • Use on trucks or other high-clearance larger vehicles; 20-25 ft detection range from reader
  • Tags are sold in batches of 50. Your location may have a facility code. Check with your maintenance department or administrator if needed
  • .......more details
02-406

LiftMaster Push Button Station Nema 4 O/C/S with Keyed Lock-Out Die-Cast Enclosure

  • Code on key is #301
50-HERK-RC2

Hercules Infrared Programming Remote Red (50-HERK-RC2)

  • Conveniently choose from 8 different preset comfort functions to adjust detection fields mounting heights relay hold interval cross traffic optimization direction recognition people/vehicle separation slow motion detection turn on/off filter functions open the door manually and much more
  • Bidirectional
  • Fine-tune the motion detector from the ground without guessing if all the settings have been received by the sensor
50-HERK2

Hercules Microwave Motion Detector for Industrial Doors

  • Opens after sensing an object.
  • Can be set up to detect vehicles separately from people and bring the two signals to two different outputs
  • Or use the two outputs to differentiate between forward and backward movements
  • Detection fields are adjustable - manually or with a remote control (sold separately)
  • Can be mounted between 8.2' up to 23' with max range of 80'
  • Reference height of 23' and angle of 45 degrees
  • .......more details
TLS1CARD

LiftMaster Option Board for L4 L5

  • Works in conjunction with Logic 4 & Logic 5 to provide seven field-selectable modifications
  • Including six door traffic control options
  • A means to connect External Open & Close limits by using a selectable DIP switch
  • Controls both 24V & 110V traffic lights
  • Formally known as RDGRNCARD
LMTBUL

LiftMaster Monitored Through Beam Photo Eye w/ Heater Nema 4X

  • Tested and evaluated by UL and meet UL 325 requirements.
  • Long Range powerful beam provides reliable performance.
  • Sensing distance up to 90 ft.
  • Anti-Fogging Lens
  • NEMA 4X rated
  • Wireless network mode eliminates the need to wire between operators in dual-gate applications.
  • .......more details
PS12D2A

LiftMaster Passport Power Supply Plug-In 12VDC 2A (02A1699-1/ ST122A)

  • Same as #002A1699-1
50-450

LiftMaster Interlock Switch for Sectional Door Nema 4 (Same as 50-13529)

  • Interlock switch is engaged by the door side lock and disables operator control.
LM21AFCB

LiftMaster Advance Fire Control Release Device

  • UL 864 Revision 9 compliant.
  • 3 count obstruction cycling.
  • Selectable 10 20 30 or 60-second time delay on alarm.
  • Test key switch – Floor level testing.
  • Motor voltage sensing.
  • Form C relay output.
  • .......more details
BGARMFOAM

TECHNA Barrier Gate Arm Foam Insert

  • esigned for use with the TECHNA Barrier arm this 14' roll of extruded foam offers additional protection reducing the chance of vehicle scratches •IP68 rated waterproof LED lights •Operating temperature: - 13F to 140F ( -25C - +60 C) •Weight ~2lbs
LC-36M

LiftMaster Light Curtain Monitored

  • The Monitored Light Curtain is a primary safety entrapment protection device that is compliant with UL 325.
  • IP67 Water-resistant housing anodized aluminum corrosion resistant
  • Operating Temperature: -40° F to +140° F (-40° C to +60° C)
  • Liftmaster Compatibility: LOGIC 5.0 Medium-Duty DDO8900W / LJ8900W / LJ8950W / ATSWVFOH HPH1 / HPH2 HCTDCUL Fire Door Egress
DCWALLCTL

LiftMaster Floor Level Wall Controller with LCD Display

  • Compatible with LiftMaster MAXUM Commercial Door Operators.
  • 4-line LCD display gives you access to more information at all times
  • Bringing programming troubleshooting and Diagnostics down to the floor level will save you time and money
  • Menu based user interface allows you to scroll through edit and save options and settings easily.
  • Dimensions: 3.586” W x 8.166” H x 1.732” D
S505AL

LiftMaster Monitored Small Profile Resistive Edge w/Aluminum Channel 5ft

  • Meets 2016 UL 325 requirements Edge sends signal to stop and/or reverse operation when sensing obstructions
  • Fast easy to install mounts vertically or horizontally
  • Compatible with Wireless edge kit LMWEKITU Transmitter LMWETXU and LiftMaster Gate Operators with Monitored Safety Inputs
100MAPS

LiftMaster External Power Supply 110VAC Input 12VDC 2000mA

  • Provides enough power to operate two LC-36A light curtains.
  • Includes 38' cable leads