Type: control programming and diagnostics unit for devices equipped with
BusT4 connector
Technology adopted: half duplex 19200 Bps serial connection on differential bus for delivery of commands modification or parameters and monitoring of diagnostic data
Maximum number of hourly commands: 64
Event log: storage capacity of 400 events
Operating temperature: from –20°C to +55°C
• Dimensions (mm): 107 x 61 x h 20 (with wall-mounting support: 125 x 70 x h 32)
1 HP 460 volt 3 phase Industrial Continuous Duty Jackshaft Operator
Ideal for Sectional Doors Rolling Steel
Monitored logic board with integral 372Mhz radio receiver that can hold up to 20 transmitters (MK-00647/ MK-00653/ MK-00659) or 200 of the 1 channel hand held transmitters (MK-00660).
N-1 Through-beam (MK-00649) photocells included. Other options available.
3-btn open/stop/close (02-103) wall control station included
1 HP208V 1 PH Industrial Continuous Duty Jackshaft Operator
Ideal for Sectional Doors Rolling Steel
Monitored logic board with integral 372Mhz radio receiver that can hold up to 20 transmitters (MK-00647/ MK-00653/ MK-00659) or 200 of the 1 channel hand held transmitters (MK-00660).
N-1 Through-beam (MK-00649) photocells included. Other options available.
3-btn o/s/c (02-103) wall control station included