This modification provides a washdown motor N-4X corrosion proof stainless steel control box enclosure waterproof drive and limit chain and a corrosion proof three-button station.
For options M & U Micanan N-4X photocells are supplied
Modification includes an explosion-proof motor explosion proof fittings operator mounted explosion-proof electrical control enclosure and n explosion-proof three button station.
A safepack module is used as an "Intrinsically Safe Barrier Relay" and in hazardous locations with non-voltage producing sensors allowing the user to use a N.O. non-monitored sensing edge.
Standard features include: N-4/12 12" x 10" x 6" panel B-2 C-2 D1 E2 T TS Mid-stop control functions Time delay on reverse On-board radio receiver hinged cover backplate primary fuses in panel
If PBS on cover required an additional charge will apply
If panel not ordered with an operator an additional charge will apply