K20-8100M-DC is a 1HP Motor Replacement Kit (90VDC BM CF). For use with various LiftMaster® 1HP 1-Phase Commercial Door Operators and Gate Operator Systems
Electromechanical sensing edge for use on Cornell doors.
•The MC22 is manufactured to exact specifications.
•The MC22 is completely flexible and will contour to curved surfaces.
•Touch sensitive signaling allows immediate reversing or stopping of motion.
•Temperature range: -30F to 155F
•Lead wire: 22 gauge universal
•Sensitivity: nominal 6-8 PSI
•2 wire NO configuration
•Vertical or horizontal mount
•One year warranty
The Silencio operators have integrated noise reducing enhancements which make it 4X QUIETER than the Premium Trolley Apartment model (OTBH-A.05).
A low headroom apartment type garage door operator designed for use on industrial standard lift sectional doors with high cycling daily frequency requirements
Mounting (Low Headroom Design): Ceiling-mounted with only 6.25" headroom clearance required below the tracks. For indoor use only.
Dimensions: Back Room: door height + 4'5" (1350 mm)
Head Room For Tracks: 5.625" (143 mm) above the highest point of door travel
Gearhead style commercial door operators employ lubricated gears for heavy industrial high cycle applications.
GH-style operators include a floor level chain hoist to ease manual operation in an emergency or power outage.
Hoist wheel is easily moved to Right or Left hand side of unit eliminating the need to order right or left hand mounting.
MyQ Technology enables you to securely monitor and control your facility operator with your smartphone tablet or computer. Internet Gateway 828LM required.
Security +2.0 radio receiver safeguards your facility - with every click a new code is sent to the commercial door operator so the door opens only for you.
Timer-To-Close: Conveniently and confidently closes the commercial door automatically after a predetermined amount of time has elapsed for added security and peace of mind.
Includes: access door with a hole for a standard or fire department padlock interior micro switch knock out for Knox key switch and standard cylinder lock
Two options for automatic gate access: 1) micro switch is activated when the padlock is removed and the front panel is opened or 2) via Knox key switch
NOTE: fire department padlock and Knox switch NOT provided
Light curtain made up of a series of thru-beam photo eyes designed to provide a dense barrier of protection for motorized or high speed doors.
Ideal for environments that require expanded protection for protruding parts that may not be detected by standard single-beam photo eyes mounted 6" above the floor.
Ideal for pre-2010 installations not requiring a monitored solution.
Harness Replacement Kit. Compatible with LiftMaster® IHSL24UL & INSL24UL Series Industrial Heavy Duty Slide and Industrial Lite Duty Slide Gate Operators
Motor and controller: Continuous duty rated DC Motor with controller producing a powerful soft start/soft stop output of 2000 Newtons of force to drive commercial sectional doors while reducing mechanical impacts that cause premature wear of door components
NEMA 4X rated controller case: ZAP Controllers and push buttons are NEMA 4X compliant as a standard
Wiring type: C2 (factory default) B2 failsafe is standard with the addition of approved photo eye.
Radio control and external receiver terminals: Terminal strip provided inside the controller to provide quick convenient connections for adding external radio control receivers from any desired manufacturer
May be used in two different ways: as an OPEN only control (all LiftMaster operators) or as an OPEN/CLOSE control (only LiftMaster operators with types B2 and S2 control wiring).
In the latter case pulling the cord will open a fully closed door close a fully opened door and reverse a closing door.
Pulling the cord whlie the door is opening will either have no effect (type B2 wiring) or will stop the door (Solid State Logic Control Board).
A safepack module is used as an "Intrinsically Safe Barrier Relay" and in hazardous locations with non-voltage producing sensors allowing the user to use a N.O. non-monitored sensing edge.
Shutters can be up to 13'- 6 inches wide and 12 feet tall with UL labels Class A B or C while still being able to function as normal counter rolling shutters.
Oversized fire shutters can be manufactured up to 20 feet wide
Model 7500 fire shutters can be installed with either a manual lift external motors a hand crank with or without automatic testing tubular models with the option of automatic testing
Along with UL labels that will automatically close the fire shutters for either 3 1½ or ¾ hours the fire shutters can also be manufactured with smoke protection
Available finishes: Hot-dipped galvanized steel with an optional baked-on gray polyester enamel coating or 304 stainless steel with a number 4 finish flat profile
The viscous speed governor can be set to automatically close the fire shutters at speeds of 6 inches per second up to 24 inches per second complying with NFPA 80 specifications.