CPS3CARD

LiftMaster Option Card Only (41K0811)

  • Works with all commercial Logic versions L2 L3 L4 L5
  • Use with CPS-U to add a second set of eyes to the operator
  • Allows activation of Timer-To-Close without CPS-U
  • Simply plugs into Logic board
  • Cut resistors on JU1 & R16 to activate timer feature
  • Same as 041K0811
02-406

LiftMaster Push Button Station Nema 4 O/C/S with Keyed Lock-Out Die-Cast Enclosure

  • Code on key is #301
K21-38158

LiftMaster Current Sense Harness Kit 3PH L5

  • This is a Current Sense Harness (230/460/575V) Replacement Kit.
  • Compatible with various LiftMaster® 3 Phase Logic 5.0 Commercial Door Operators; manufactured after February 2016.
  • Complete replacement kit includes: (2) current sense harnesses of different lengths to accommodate all models.
  • Models manufactured before February 2016 DO NOT feature current sense technology.
  • We highly recommend replacing the existing boards with an updated Logic 5.0 system that utilizes current sense technology
  • Refer to the following replacement boards for compatible upgrades: K001D8395 1PH/3PH Logic Board for all L5 models K001D8397 3PH/L5 Power Board 230/460V
  • .......more details
LM21AFCB

LiftMaster Advance Fire Control Release Device

  • UL 864 Revision 9 compliant.
  • 3 count obstruction cycling.
  • Selectable 10 20 30 or 60-second time delay on alarm.
  • Test key switch – Floor level testing.
  • Motor voltage sensing.
  • Form C relay output.
  • .......more details
RGL-CTL

LiftMaster Compact Red/Green Traffic Light 12-24V LED

  • The LiftMaster Hi-Intensity Red/Green LED Traffic Light is designed for use in both indoor and outdoor applications where signaling and traffic control are required.
  • The Traffic Light puts out hi-intensity red and green beams that are well suited to areas that require a controlled field of view for narrow lane signaling and daylight visibility.
  • The Traffic Light is compatible with Logic 3/4/5.0 operators that can accommodate the TLS1CARD and RDGRNCARD
  • Supply Voltage And Current: 15-30 volts DC preferred AC acceptable
  • Connections: Integral 4-Pin Connector with pig tail
  • Operating Temperatures: -40° to +50° C (-40° to +122° F)
  • .......more details
CPS3-N4

LiftMaster Option Card with CPS-UN4 Eyes for applications requiring 2 sets of photocells

  • For applications requiring two sets of photoeyes in a damp location
  • Range up to 45ft water dust and corrosion proof eyes (Nema 4x rating)
  • Works with Logic 3 4 5 Commercial Operators
  • Includes Durable steel brackets - floor or track mounting
  • Kit Inludes one set of CPS-UN4 and one CPS3 card ( CPSIII )
LC-36A

LiftMaster Light Curtain **discontinued

  • Must be used with a primary entrapment device and be installed along the vertical plane of the door.
  • Color-coded transmitter and receiver for easy identification.
  • Provides 36 in. of effective height coverage to increase the area of protection.
  • Multiple sets of LC-36A curtains can be mounted on a door providing coverage flexibility.
  • Maximum door width of 33 ft. ensures coverage for most commercial doors.
  • Eight (8) LEDs per side and 22 cross-beams produce an invisible curtain of infrared light for maximum detection capability.
  • .......more details
K30-205-E

LiftMaster Boot Red

  • Also known as: 30-205-E 30205E
  • Replacement button cover for 02-406 station
K23-20523

LiftMaster Interlock Switch 125/250VAC 3A N4

  • For use with various LiftMaster® Commercial Door Operators
LM21XPBBVB

LiftMaster Extended Performance Fire Door Release Device with Battery Backup and Voice Board ** No Longer Available

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
50-HERK2

Hercules Microwave Motion Detector for Industrial Doors

  • Opens after sensing an object.
  • Can be set up to detect vehicles separately from people and bring the two signals to two different outputs
  • Or use the two outputs to differentiate between forward and backward movements
  • Detection fields are adjustable - manually or with a remote control (sold separately)
  • Can be mounted between 8.2' up to 23' with max range of 80'
  • Reference height of 23' and angle of 45 degrees
  • .......more details
LMTBU

LiftMaster Monitored Through Beam Photo Eye Nema 4X ** To exent of inventory

  • Meets 2016 UL 325 requirements
  • Long Range powerful beam provides reliable performance.
  • Sensing distance up to 90 ft.
  • Anti-Fogging Lens
  • NEMA 4X rated
  • Wireless network mode eliminates the need to wire between operators in dual-gate applications.
  • .......more details
CPS-RN4

LiftMaster Retro-Reflective Commercial Protector System with Nema 4 Enclosure ** DISCONTINUED

  • Utilizes a sending/receiving retro-reflective photo-eye and a specially designed polarized reflector that increases obstruction detection reliability
  • Polarized photo-eye design for a safe retro-reflective photo-eye system
  • Designed as a normal open circuit but not a self-monitoring system (does not incorporate industrial code technology)
  • Range up to 30 ft - indoor use only
  • 24VAC operation
  • Color: Yellow
  • .......more details