Devanco Canada

 
User Name:
Password:
Remember Me:
Forgot your password
Request a Login

LMSC1000

LiftMaster RFID Long Range Vehicle Access Card Reader

  • Easy wall or post mount vehicle tag/prox card reader can service an entire facility parking garage gated community/HOA or guarded properties.
  • Integrates into (CAPXL CAP2D) Liftmaster PPWR Passport Receiver and LiftMaster CSW24U 24 VDC Commercial Swing Gate Operator CSL24UL HCTDCUL systems to give access via encrypted-digital code.
  • Opens swing or slides gates from 20-30 feet distance
  • 26-bit Wiegand Interface console
  • Encrypted binary protocol signal
  • Helpful Programming/Testing/Function tri-color LEDs on both reader face and Wiegand console
  • Dimensions: 10.25" W x 10.25" L x 1.25" D
  • LiftMaster KSC12-3A Power Adapter RFID 12V 3A included ***Requires socket/outlet in weatherproof enclosure
  • Includes 2-way adjustable mounting bracket w/ U-bolts
02-411

LiftMaster Pull Switch Assembly Nema 4

  • May be used in two different ways: as an OPEN only control (all LiftMaster operators) or as an OPEN/CLOSE control (only LiftMaster operators with types B2 and S2 control wiring).
  • In the latter case pulling the cord will open a fully closed door close a fully opened door and reverse a closing door.
  • Pulling the cord whlie the door is opening will either have no effect (type B2 wiring) or will stop the door (Solid State Logic Control Board).
02-103L

LiftMaster Push Button Station 3-btn Surface Mount O/C/S Nema 1 with Maintenance Alert LED

  • PBS-3
  • Open-Close-Stop
  • Momentary contact
  • Nema 1
  • Works with Liftmaster MH commercial operator
  • Dimensions: 5-5/16" H x 2-3/8" W x 1-13/16" D
  • .......more details
23-10916

LiftMaster Interlock Switch SPDT

  • Interlock switch for LM commercial door openers with hoist disconnects
  • 15A 125/250VAC
LM21XPBB

LiftMaster Extended Performance Fire Door Release Device with Battery Backup

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
AFB120

LiftMaster Fire Access Box w/Micro Switch & Knox Key Switch Option

  • ll-in-one fire access box
  • Includes: access door with a hole for a standard or fire department padlock interior micro switch knock out for Knox key switch and standard cylinder lock
  • Two options for automatic gate access: 1) micro switch is activated when the padlock is removed and the front panel is opened or 2) via Knox key switch
  • NOTE: fire department padlock and Knox switch NOT provided
LM21XP

LiftMaster Extended Performance Fire Door Release Device

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
02-103LGO-1

Push Button Station 3-btn Surface Mount O/C/S Nema 1 For LGO Ops only

  • PBS-3R
  • Open-Close-Stop
  • Works with Liftmaster LGO commercial operator
  • Also known as: 02-103LGO1 02103LGO1
  • Dimensions: 5-5/16" H x 2-3/8" W x 1-13/16" D
  • Normally Open contact on Stop therefore it won’t work on any other LiftMaster operator besides the LGO. The 02-103 will work on all operators.
  • .......more details
LMUNTG

LiftMaster Glass Mount Parking Pass Tag Sold Per Card

  • A security-enhanced RFID passive transmitter for use with the LIftMaster LMSC1000 Long Range Vehicle Access-Card Reader.
  • Glass-mount means it can be affixed to either the windshield of a car or to the headlight housing of the vehicle
  • Aligns with the cone-shaped detection zone from LiftMaster RFID Reader and activates it to open gate barrier
  • Added security of single mount use: shuts off if removed after adhering to a surface
  • Use on trucks or other high-clearance larger vehicles; 20-25 ft detection range from reader
  • Tags are sold in batches of 50. Your location may have a facility code. Check with your maintenance department or administrator if needed
  • .......more details
02-410

LiftMaster Commercial Key Control Station Open-Close and Off with Stop Button

  • Outdoor Surface Mount Nema 4/12 station
  • Standard key cylinder
  • Open/Close spring return to center (off)
  • Key removable in center position only
  • With Stop button
02-410B

LiftMaster Commercial Key Control Station Open-Close and Off with Stop Button and BEST Cylinder

  • Outdoor Surface Mount Nema 4/12 station
  • Standard key cylinder is replaced with BEST cylinder
  • Open/Close spring return to center (off)
  • Key removable in center position only
  • With Stop button
02-409

LiftMaster Key Switch 2-Position Nema 4/12

  • Two Position Key Control Station
  • Outdoor Surface Mt. (NEMA 4/12)
  • Tamperproof
  • Die cast metal enclosure with standard key cylinder
  • OPEN/CLOSE spring return to center (OFF) key removable in center position only. Should only be used on operators wired for constant pressure to open and close (all LiftMaster industrial operators with type D control wiring).
  • Dimiensions: 3" x 3.2" x 4.2"
  • .......more details
02-404

LiftMaster Key Switch Assembly On/Off Nema 4/12 **DISCONTINUED

  • Two Position Key Control Station
  • Outdoor Surface Mt. (NEMA 4/12)
  • Non-Tamperproof
  • OPEN/CLOSE spring return to center (OFF) key removable in center position only.
  • Should only be used on operators wired for constant pressure to open and close (all LiftMaster industrial operators with type D control wiring).
  • Die cast metal enclosure
  • .......more details
LM21XPBBVB

LiftMaster Extended Performance Fire Door Release Device with Battery Backup and Voice Board ** No Longer Available

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
02-409B

LiftMaster Key Switch with Best Cylinder

  • Two Position Key Control Station
  • Outdoor Surface Mt. (NEMA 4/12)
  • Tamperproof
  • Die cast metal enclosure with BEST cylinder (construction core included)
  • OPEN/CLOSE spring return to center (OFF) key removable in center position only. Should only be used on operators wired for constant pressure to open and close (all LiftMaster industrial operators with type D control wiring).
  • Dimiensions: 3" x 3.2" x 4.2"
  • .......more details
02-711

LiftMaster Nema 7/9 Ceiling Switch Pull Control

  • Single Pull Switch Control
  • Hazardous Area Overhead Mt. (NEMA 7/9)
  • Die cast hazardous area enclosure
  • May be used in two different ways; as an OPEN only control (all LiftMaster operators) or as an OPEN/CLOSE control (only LiftMaster operators with types B2 and S2 control wiring). In the latter case pulling the cord will open a fully closed door close a fully opened door and reverse a closing door.
  • Pulling the cord whlie the door is opening will either have no effect (type B2 wiring) or will stop the door (Solid State Logic Control Board).
  • WARNING: When used on most industrial operators this control will not stop the door. Use another control that has a STOP button in conjunction with this control.
  • .......more details