LiftMaster Hoist Interlock Switch SPDT

  • Interlock switch for LM commercial door Openers with hoist disconnects
  • 15A 125/250VAC
LMUNTG

LiftMaster Glass Mount Parking Pass Tag Sold Per Card

  • A security-enhanced RFID passive transmitter for use with the LIftMaster LMSC1000 Long Range Vehicle Access-Card Reader.
  • Glass-mount means it can be affixed to either the windshield of a car or to the headlight housing of the vehicle
  • Aligns with the cone-shaped detection zone from LiftMaster RFID Reader and activates it to open gate barrier
  • Added security of single mount use: shuts off if removed after adhering to a surface
  • Use on trucks or other high-clearance larger vehicles; 20-25 ft detection range from reader
  • Tags are sold in batches of 50. Your location may have a facility code. Check with your maintenance department or administrator if needed
  • .......more details
50-CP4

LiftMaster Sensing Probe Free Exit 100ft Lead

  • Self-contained free exit system designed to detect moving vehicle and open your automatic gate.
  • Can be installed above or below ground
  • Connects directly to any gate operator without an external output board.
  • Works with powered or solar gates.
  • SPECIFICATIONS: Cable Lead Length: 100 ft.
  • Power Requirements: 8-24 VAC oe 8-30 CSX
  • .......more details
LM21XPBB

LiftMaster Extended Performance Fire Door Release Device with Battery Backup

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
TLS1CARD

LiftMaster Option Board for L4 L5

  • Works in conjunction with Logic 4 & Logic 5 to provide seven field-selectable modifications
  • Including six door traffic control options
  • A means to connect External Open & Close limits by using a selectable DIP switch
  • Controls both 24V & 110V traffic lights
  • Formally known as RDGRNCARD
K26-438

LiftMaster Artisan Timer

  • For use with various LiftMaster® Speed Jack Commercial Door Operators
  • Also known as: 26-438 AB117-00121 G26438 438USA
  • The DIP switches are used to set the time delay period between 1 and 1024 seconds.
  • The timer has an internal 1 second delay opening of the DIP switches adds their corresponding value to that internal delay.
  • The switches to the right are all opened for a total delay of 1023 seconds adding that to the internal 1 second provides the full 1024 seconds.
  • Any time delay from 1 to 1024 seconds can be achieved by opening the appropriate switches.
  • .......more details
LM56A

LiftMaster Magnetic Proximity Reed Switch

  • Normally Open magnetic sealed reed switch; proximity switch
  • Used for overhead door contacts.
02-103L

LiftMaster Push Button Station 3-btn Surface Mount O/C/S Nema 1 with Maintenance Alert LED

  • PBS-3
  • Open-Close-Stop
  • Momentary contact
  • Nema 1
  • Works with Liftmaster MH commercial operator
  • Dimensions: 5-5/16" H x 2-3/8" W x 1-13/16" D
  • .......more details
LM21XP

LiftMaster Extended Performance Fire Door Release Device

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
02-411

LiftMaster Pull Switch Assembly Nema 4

  • May be used in two different ways: as an OPEN only control (all LiftMaster operators) or as an OPEN/CLOSE control (only LiftMaster operators with types B2 and S2 control wiring).
  • In the latter case pulling the cord will open a fully closed door close a fully opened door and reverse a closing door.
  • Pulling the cord whlie the door is opening will either have no effect (type B2 wiring) or will stop the door (Solid State Logic Control Board).
02-410B

LiftMaster Commercial Key Control Station Open-Close and Off with Stop Button and BEST Cylinder

  • Outdoor Surface Mount Nema 4/12 station
  • Standard key cylinder is replaced with BEST cylinder
  • Open/Close spring return to center (off)
  • Key removable in center position only
  • With Stop button
LM21XPBBVB

LiftMaster Extended Performance Fire Door Release Device with Battery Backup and Voice Board ** No Longer Available

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
LMSC1000

LiftMaster RFID Long Range Vehicle Access Card Reader

  • Easy wall or post mount vehicle tag/prox card reader can service an entire facility parking garage gated community/HOA or guarded properties.
  • Integrates into (CAPXL CAP2D) Liftmaster PPWR Passport Receiver and LiftMaster CSW24U 24 VDC Commercial Swing Gate Operator CSL24UL HCTDCUL systems to give access via encrypted-digital code.
  • Opens swing or slides gates from 20-30 feet distance
  • 26-bit Wiegand Interface console
  • Encrypted binary protocol signal
  • Helpful Programming/Testing/Function tri-color LEDs on both reader face and Wiegand console
  • .......more details
50800

LiftMaster RBMA Electric Treadle Nema 4/12 5ft long

  • Five feet long.
  • OPEN only (all LiftMaster operators) or SAFETY only (LiftMaster operators with type B2 C2 L2 T T1 or TS control wiring) after vehicle passes over treadle.
  • The weight of the vehicle compresses an electric switch which sends an open signal to the door.
  • Requires a 2-wire connection to the operator but does not require power to function
50-HERK-RC2

Hercules Infrared Programming Remote Red (50-HERK-RC2)

  • Conveniently choose from 8 different preset comfort functions to adjust detection fields mounting heights relay hold interval cross traffic optimization direction recognition people/vehicle separation slow motion detection turn on/off filter functions open the door manually and much more
  • Bidirectional
  • Fine-tune the motion detector from the ground without guessing if all the settings have been received by the sensor
50-HERK2

Hercules Microwave Motion Detector for Industrial Doors

  • Opens after sensing an object.
  • Can be set up to detect vehicles separately from people and bring the two signals to two different outputs
  • Or use the two outputs to differentiate between forward and backward movements
  • Detection fields are adjustable - manually or with a remote control (sold separately)
  • Can be mounted between 8.2' up to 23' with max range of 80'
  • Reference height of 23' and angle of 45 degrees
  • .......more details
20W33A

LiftMaster Solar Kit 33-AH 12V ***Kit includes: 1x SP20W12V 1x A12330SGLPK & 1x K94-37236***

  • Kit includes: SP20W12V (1) SOLAR-PANEL KIT12V20W A12330SGLPK (1) BATTERY 12V33AHSINGLE K94-37236 (1) UNIVERSAL SOLAR HARNESS KIT-7AH & 33AH
  • Compatible with: RSL12ULMC gate opener
G50402

LiftMaster Timer Defeat Hold Open Switch 50-12860

  • Allows for the auto-close timer to be manually disabled
02-410

LiftMaster Commercial Key Control Station Open-Close and Off with Stop Button

  • Outdoor Surface Mount Nema 4/12 station
  • Standard key cylinder
  • Open/Close spring return to center (off)
  • Key removable in center position only
  • With Stop button
AFB120

LiftMaster Fire Access Box w/Micro Switch & Knox Key Switch Option

  • ll-in-one fire access box
  • Includes: access door with a hole for a standard or fire department padlock interior micro switch knock out for Knox key switch and standard cylinder lock
  • Two options for automatic gate access: 1) micro switch is activated when the padlock is removed and the front panel is opened or 2) via Knox key switch
  • NOTE: fire department padlock and Knox switch NOT provided